Safe Decontamination & Infection Control Support
Our HTM 01-05 compliance service focuses on the Health Technical Memorandum (HTM) 01-05 guidelines, which govern decontamination and infection control in primary care dental practices.
HTM 01-05 Compliance Made Simple
How we help
Why it matters
What Is HTM 01-05?
HTM 01-05 (Decontamination in Primary Care Dental Practices) is the Department of Health guidance that sets out how dental practices in England should clean, disinfect, sterilise and store reusable dental instruments. The CQC uses it as a benchmark when assessing whether a practice is safe, particularly under Regulation 12 (Safe care and treatment) and Regulation 15 (Premises and equipment) of the Health and Social Care Act 2008 (Regulated Activities) Regulations 2014.
HTM 01-05 Compliance: Essential Quality Requirements vs Best Practice
The guidance works on two levels:
- Essential quality requirements – the minimum standard every practice must meet, such as validated equipment, documented daily testing, safe manual or ultrasonic cleaning, and clear separation of dirty and clean processes.
- Best practice – the higher standard practices should work towards, for example using a washer-disinfector instead of manual cleaning, a dedicated decontamination room separate from the surgery, and data loggers to record every cycle.
We help you meet the essential requirements first, then build a realistic, budget-friendly plan to move towards best practice.
The Decontamination Cycle
HTM 01-05 follows instruments through every stage of reuse. Each step needs a safe, documented process:
- Transport – moving used instruments safely from the surgery to the decontamination area.
- Cleaning – manual cleaning, ultrasonic bath or washer-disinfector to remove debris and contamination.
- Inspection – checking every instrument under illuminated magnification before sterilisation.
- Sterilisation – processing in a validated steam steriliser (autoclave).
- Storage – storing sterilised instruments correctly, wrapped or unwrapped, within the permitted timeframes.
- Use and return – using instruments in the surgery and returning them to start the cycle again.
What Our HTM 01-05 Support Covers
Gap Analysis & Six-Monthly Audits
HTM 01-05 expects practices to audit their decontamination processes at least every six months. We carry out a full review against the guidance, often using the Infection Prevention Society (IPS) Dental Audit Tool, and give you a clear, prioritised action plan.
Equipment Testing & Validation Records
All decontamination equipment must be validated, tested, maintained and serviced in line with the manufacturer’s instructions and HTM 01-05. We check that you have:
- Daily autoclave tests (such as automatic control and steam penetration tests) recorded in a logbook.
- Periodic tests for washer-disinfectors and ultrasonic baths.
- Validation at installation and annually after that.
- A written scheme of examination and an in-date pressure vessel inspection for sterilisers, as required by the Pressure Systems Safety Regulations 2000.
- Sterilisation cycle records kept for at least two years.
Decontamination Room Layout & Workflow
We review your local decontamination unit (LDU) or surgery set-up to make sure there is a clear dirty-to-clean workflow, separate hand-wash and instrument sinks, and suitable zoning and storage, so instruments never re-enter a dirty area once processed.
Instrument Storage
We check that sterilised instruments are stored, labelled and used within the timeframes set by the guidance, and that wrapped and unwrapped instruments are kept in suitable conditions.
Dental Unit Waterlines & Legionella
We make sure your Legionella risk assessment is in place and up to date, and that waterline flushing, disinfection and monitoring are carried out and recorded.
Hand Hygiene, PPE, Sharps & Waste
We review hand hygiene, personal protective equipment, sharps safety and clinical waste handling (in line with HTM 07-01), so your wider infection control arrangements support your decontamination process.
Policies, Logbooks & Staff Training
We provide clear, practice-specific infection control policies, test logbooks and checklists, help you appoint and support an infection control lead, and make sure staff training and immunisation records are ready for inspection.
How Our HTM 01-05 Support Works
- Initial review – we look at your current decontamination set-up, equipment records, policies and previous audits.
- Gap analysis & action plan – you get a clear report showing what meets the essential requirements, what needs fixing, and steps towards best practice.
- Documentation & templates – we provide the policies, logbooks and checklists your team needs to run repeatable, auditable processes.
- Ongoing audit support – we help you complete your six-monthly audits and prepare for CQC inspection with confidence.
Common HTM 01-05 Gaps That Cause Problems at Inspection
- Missing or incomplete daily autoclave test records.
- Out-of-date equipment validation or pressure vessel certificates.
- No clear dirty-to-clean workflow in the decontamination area.
- Infection control audits not completed every six months.
- Instruments stored beyond the permitted timeframes or without proper labelling.
- Legionella risk assessment not reviewed or waterline records missing.
- Staff training, competency and immunisation records not kept up to date.
Infection control is just one part of inspection readiness. See our dental CQC inspection checklist for everything else inspectors review, and our guide to dental practice policies and procedures for the policies your team needs.
HTM 01-05 Frequently Asked Questions
Is HTM 01-05 a legal requirement?
HTM 01-05 is guidance rather than law, but the CQC uses it to judge whether a dental practice provides safe care. Meeting at least the essential quality requirements is the main way to show you comply with the relevant regulations. Some related requirements, such as pressure vessel inspections, are legal duties in their own right.
How often should a dental practice carry out an HTM 01-05 audit?
HTM 01-05 recommends auditing decontamination processes at least every six months, with an action plan for any issues found.
Do we need a washer-disinfector to be compliant?
No. Manual or ultrasonic cleaning can meet the essential quality requirements when done correctly and documented. A washer-disinfector is part of best practice, and we can help you plan for one.
What records will a CQC inspector expect to see?
Typically daily and periodic equipment test records, validation and servicing certificates, pressure vessel inspection reports, infection control audits, policies, staff training records and your Legionella risk assessment.
Does HTM 01-05 apply in Wales and Scotland?
HTM 01-05 applies to dental practices in England. Wales follows its own version, WHTM 01-05, and Scotland has separate guidance (SHTM 01-05).
How long can sterilised instruments be stored?
Storage times depend on whether instruments are wrapped or unwrapped and where they are kept. Wrapped instruments stored in suitable conditions can be kept for much longer than unwrapped instruments. We will check your storage arrangements against the current guidance.
Other Services we Offer
CQC Compliance Support
Policies & Procedures Management
GDPR & Data Protection Compliance
Inspection Preparation Support
Let’s Simplify Your Compliance Together.
Contact us today to talk through your practice’s compliance needs and take the first step towards confident, inspection-ready compliance.